How global warming and building envelope will change buildings energy use in central Europe, Applied Energy, vol.97, pp.999-1004, 2012. ,
DOI : 10.1016/j.apenergy.2012.03.023
Analysis of the effect of global climate change on ground source heat pump systems in different climate categories, Renewable Energy, vol.78, pp.219-225, 2015. ,
DOI : 10.1016/j.renene.2015.01.017
Study of technical, economical and environmental viability of ground source heat pump system for Himalayan cities of India, Renewable and Sustainable Energy Reviews, vol.48, pp.48-452, 2015. ,
DOI : 10.1016/j.rser.2015.04.008
Recent research and applications of ground source heat pump integrated with thermal energy storage systems: A review, Applied Thermal Engineering, vol.71, issue.1, pp.71-142, 2014. ,
DOI : 10.1016/j.applthermaleng.2014.06.040
Optimization of solar assisted ground source heat pump system for space heating application by Taguchi method and utility concept, Energy Build, p.82, 2014. ,
A study on energy and CO2 saving potential of ground source heat pump system in India, Renewable and Sustainable Energy Reviews, vol.32, pp.278-293, 2014. ,
DOI : 10.1016/j.rser.2014.01.031
Potential Reduction in CO2 Emission and Saving in Electricity by Ground Source Heat Pump System for Space Heating Applications-A Study on Northern Part of India, Procedia Engineering, vol.38, pp.38-970, 2012. ,
DOI : 10.1016/j.proeng.2012.06.123
Performance study of a ground heat exchanger based on the multipole theory heat transfer model, Energy Build, pp.65-231, 2013. ,
Optimization of ground heat exchanger parameters of ground source heat pump system for space heating applications, Energy, vol.78, pp.78-573, 2014. ,
DOI : 10.1016/j.energy.2014.10.045
Optimization of operating parameters of ground source heat pump system for space heating and cooling by Taguchi method and utility concept, Applied Energy, vol.116, pp.76-85, 2014. ,
DOI : 10.1016/j.apenergy.2013.10.065
Effects of depth and material property variations on the ground temperature response to heating by a deep vertical ground heat exchanger in purely conductive media, Geothermics, vol.51, pp.9-30, 2014. ,
DOI : 10.1016/j.geothermics.2013.10.002
Improvement of borehole thermal energy storage design based on experimental and modelling results, Energy Build, pp.77-393, 2014. ,
Thermal performance and economic evaluation of double U-tube borehole heat exchanger with three different borehole diameters, Energy Build, pp.67-217, 2013. ,
Performance of borehole ground heat exchangers under thermal loads from a school building: full-scale experiment in Melbourne, Proceedings of World Geothermal Congress, 2015. ,
Analytical simulation of groundwater flow and land surface effects on thermal plumes of borehole heat exchangers, Applied Energy, vol.146, 2015. ,
DOI : 10.1016/j.apenergy.2015.02.035
Fang, A moving finite line source model to simulate borehole heat exchangers with groundwater advection, Int. J. Therm. Sci, p.50, 2011. ,
A passive design strategy for a horizontal ground source heat pump pipe operation optimization with a non-homogeneous soil profile, Energy Build, pp.61-100, 2013. ,
Numerical and experimental analysis of a horizontal ground-coupled heat pump system, Building and Environment, vol.42, issue.3, pp.42-1126, 2007. ,
DOI : 10.1016/j.buildenv.2005.11.027
Experimental and modeling analysis of a ground source heat pump system, Applied Energy, vol.109, pp.328-336, 2013. ,
DOI : 10.1016/j.apenergy.2012.11.025
In-field performance analysis of ground source cooling system with horizontal ground heat exchanger in Tunisia, Energy, vol.61, pp.61-319, 2013. ,
DOI : 10.1016/j.energy.2013.08.054
Heat transfer in a U-Bend pipe: Dean number versus Reynolds number, Sustainable Energy Technologies and Assessments, vol.11, pp.11-148, 2015. ,
DOI : 10.1016/j.seta.2015.01.001
Heat transfer analysis of boreholes in vertical ground heat exchangers, International Journal of Heat and Mass Transfer, vol.46, issue.23, pp.4467-4481, 2003. ,
DOI : 10.1016/S0017-9310(03)00270-9
Simulation study on the thermal performance of vertical U-tube heat exchangers for ground source heat pump system, Applied Thermal Engineering, vol.79, p.79, 2015. ,
DOI : 10.1016/j.applthermaleng.2014.12.068
The performance prediction of ground source heat pump system based on monitoring data and data mining technology, Energy Build, p.127, 2016. ,
A composite cylindrical model and its application in analysis of thermal response and performance for energy pile, Energy Build, pp.324-332, 2014. ,
A method and case study of thermal response test with unstable heat rate, Energy Build, p.48, 2012. ,
Vertical geothermal borefields, ASHRAE J, vol.52, pp.20-28, 2010. ,
URL : https://hal.archives-ouvertes.fr/hal-00564405
Validity ranges of three analytical solutions to heat transfer in the vicinity of single boreholes, Geothermics, vol.38, issue.4, 2009. ,
DOI : 10.1016/j.geothermics.2009.07.002
URL : https://hal.archives-ouvertes.fr/hal-00509595
Experimental Methods for Engineers, 2007. ,
Experimental study of solar energy storage and space heating using solar assisted ground source heat pump system for Indian climatic conditions, Energy and Buildings, vol.139, pp.139-569, 2017. ,
DOI : 10.1016/j.enbuild.2017.01.041
Experimental study of thermal performance of a ground source heat pump system installed in a Himalayan city of India for composite climatic conditions, Energy and Buildings, vol.131, p.131, 2016. ,
DOI : 10.1016/j.enbuild.2016.09.034
Soil temperature distribution around a U-tube heat exchanger in a multi-function ground source heat pump system, Applied Thermal Engineering, vol.29, issue.17-18, pp.29-3679, 2009. ,
DOI : 10.1016/j.applthermaleng.2009.06.025
Simulation and experiment on the thermal performance of U-vertical ground coupled heat exchanger, Applied Thermal Engineering, vol.26, issue.14-15, pp.26-1564, 2006. ,
DOI : 10.1016/j.applthermaleng.2005.12.007
Temperature distributions in boreholes of a vertical ground-coupled heat pump system, Renewable Energy, vol.34, issue.12, 2009. ,
DOI : 10.1016/j.renene.2009.04.032
Analysis of geo-temperature recovery under intermittent operation of ground-source heat pump, Energy Build, p.43, 2011. ,