Methodology to optimize the sizing of a corrective measure in case of leakage from a CO2 geological storage unit

Abstract : To guarantee the safety of CO2 storage operations, to meet regulatory requirements and thus to be accepted by the public, the operator of a CO2 storage site has to demonstrate that the risks are adequately managed, which includes the treatment of potential irregularities. This paper proposes a methodology to choose a corrective measure and to optimize its sizing in case of leakage from a CO2 geological storage through a semi-pervious caprock, a fault, a fractured zone or any other leakage pathway on which it is difficult to directly act. The corrective measures considered in our work are limited to fluid and pressure management practices implemented for controlling the plume migration and eventually for extracting the leaking fluid. The methodology is based on the use of the Multi-Attribute Utility Theory (MAUT) which enables multi-criteria analysis over a continuous set of alternatives. The implementation on a case study illustrates the methodology applicability. The influence of the main assumptions and uncertainties are addressed through a sensitivity analysis.
Type de document :
Article dans une revue
International Journal of Greenhouse Gas Control, Elsevier, 2015, 41, pp.285 - 301. 〈10.1016/j.ijggc.2015.06.020〉
Liste complète des métadonnées

https://hal-brgm.archives-ouvertes.fr/hal-01399017
Contributeur : Anne-Marie Pouget <>
Soumis le : vendredi 18 novembre 2016 - 11:06:43
Dernière modification le : vendredi 18 novembre 2016 - 13:22:39

Identifiants

Collections

Citation

Annick Loschetter, Jean-Charles Manceau. Methodology to optimize the sizing of a corrective measure in case of leakage from a CO2 geological storage unit. International Journal of Greenhouse Gas Control, Elsevier, 2015, 41, pp.285 - 301. 〈10.1016/j.ijggc.2015.06.020〉. 〈hal-01399017〉

Partager

Métriques

Consultations de la notice

44