Accurate and High-Precision Determination of Boron Isotopic Ratios at Low Concentration by MC-ICP-MS (Neptune)

Résumé

We report an approach for the accurate and reproducible measurement of boron isotope ratios in natural waters using an MC-ICP-MS (Neptune) after wet chemistry sample purification. The sample matrix can induce a drastic shift in the isotopic ratio by changing the mass bias. It is shown that, if no purification is carried out, the direct measurement of a seawater diluted one hundred times will induce an offset of −7‰ in the isotopic ratio, and that, for the same concentration, the greater the atomic mass of the matrix element, the greater the bias induced. Whatever the sample, it is thus necessary to remove the matrix. We propose a method adapted to water samples allowing purification of 100 ng of boron with a direct recovery of boron in 2 ml of 3% v/v HNO3, which was our working solution. Boron from the International Atomic Energy Agency IAEA-B1 seawater reference material and from the two groundwater reference materials IAEA-B2 and IAEA-B3, was chemically purified, as well as boron from the certified reference material NIST SRM 951 as a test. The reproducibility of the whole procedure (wet chemistry and MC-ICP-MS measurement) was ± 0.4‰ (2s). Accuracy was verified by comparison with positive-TIMS values and with recommended values. Seawater, being homogeneous for boron isotope ratios, is presently the only natural water material that is commonly analysed for testing accuracy worldwide. We propose that the three IAEA natural waters could be used as reference samples for boron isotopes, allowing a better knowledge of their isotopic ratios, thus contributing to the certification of methods and improving the quality of the boron isotopic ratio measurements for all laboratories.

Dates et versions

hal-00681367 , version 1 (21-03-2012)

Identifiants

Citer

Catherine Guerrot, Romain Millot, Michele Robert, Philippe Négrel. Accurate and High-Precision Determination of Boron Isotopic Ratios at Low Concentration by MC-ICP-MS (Neptune). Geostandards and Geoanalytical Research, 2011, 35 (2), pp.275-284. ⟨10.1111/j.1751-908X.2010.00073⟩. ⟨hal-00681367⟩

Collections

BRGM BRGM-DO
230 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More