Environmental surveillance of incinerators: 2006-2009 data on dioxin/furan atmospheric deposition and associated thresholds - BRGM - Bureau de recherches géologiques et minières Access content directly
Conference Papers Year : 2011

Environmental surveillance of incinerators: 2006-2009 data on dioxin/furan atmospheric deposition and associated thresholds

Abstract

In a context of installations complying with current regulations, which means low emission values from industrial plants, this article presents a compilation of recent data (2006-2009) obtained from French MSW incinerator surveillance plans with respect to atmospheric dioxin/furan deposition. Two thresholds are provided that could be used in air quality surveillance as discussed above: 5 and 16 pg TEQ/m2/d. Finally one can insist on the interest of integrated monitoring method such as Owen gauges to measure atmospheric pollution over a long period and detect anomalous situations; not always detectable during spot analysis at the source.

Domains

Mineralogy
Fichier principal
Vignette du fichier
4104-corrected.pdf (629.5 Ko) Télécharger le fichier
Origin : Files produced by the author(s)

Dates and versions

hal-00664430 , version 1 (30-01-2012)

Identifiers

  • HAL Id : hal-00664430 , version 1

Cite

Françoise Bodénan, Pascale Michel, Lise Cary, Aurélien Leynet, Patrice Piantone. Environmental surveillance of incinerators: 2006-2009 data on dioxin/furan atmospheric deposition and associated thresholds. 31st International Symposium on Halogenated Persistent Organic Pollutants DIOXIN 2011, Aug 2011, Bruxelles, Belgium. pp.4104. ⟨hal-00664430⟩