Boron isotope ratio (delta B-11) measurements in Water Framework Directive monitoring programs: comparison between double focusing sector field ICP and thermal ionization mass spectrometry

Résumé

The aim of our research was to compare delta B-11 measurements performed with thermal ionization mass spectrometry (TIMS) and sector field-inductively coupled plasma-mass spectrometry (SF-ICP-MS) and evaluate the feasibility of implementing stable isotope methods in European water framework directive (WFD) monitoring programs. The comparison was based on delta B-11 measurements of 192 ground-and surface water samples and 15 leachates of nitrate pollution source materials (organic and mineral fertilisers). The precision of delta B-11 measurements attainable with SF-ICP-MS, 2 sigma= +/- 2.6 parts per thousand; (n = 192), is as expected lower than the precision achieved by TIMS, 2 sigma= +/- 0.3 parts per thousand (n=183). However the ease of use, rapidity and availability of SF-ICP-MS on one hand and the observed variability in delta B-11 in ground-and surface water on the other (from -3.4 to +37 parts per thousand), demonstrates that using SF-ICP-MS as an isotopic screening method would promote the use of isotopic methodology for WFD monitoring. Based on the results of the different case studies it is shown that retrieving precise information on the identification of pollution sources from delta B-11 values requires reaching the best analytical precision and accuracy possible. Hence, the superior precision of TIMS advantages tracing of nitrate pollution sources. However for some cases, e. g. trying to decipher contributions between sources with really distinct delta B-11 signatures (e.g. manure and sewage effluent), SF-ICP-MS results lead to the same conclusions and can therefore be used as a first approachable screening method for the determination of delta B-11 in WFD monitoring programs.

Dates et versions

hal-00558748 , version 1 (24-01-2011)

Identifiants

Citer

Kristof Tirez, Wilfried Brusten, David Widory, Emmanuelle Petelet-Giraud, Agnès Brenot, et al.. Boron isotope ratio (delta B-11) measurements in Water Framework Directive monitoring programs: comparison between double focusing sector field ICP and thermal ionization mass spectrometry. Journal of Analytical Atomic Spectrometry, 2010, 25 (7), p. 964-974. ⟨10.1039/C001840F⟩. ⟨hal-00558748⟩

Collections

BRGM
165 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More